7 research outputs found

    Digital image processing for noise reduction in medical ultrasonics

    Get PDF

    Speed of sound index for liver steatosis estimation: a reliability study in normal subjects

    Get PDF
    PURPOSENon-alcoholic fatty liver disease (NAFLD) is the most widespread type of chronic liver disease in the Western countries. Ultrasound (US) is widely used for NAFLD staging. The Resona 7 US system (Mindray Bio-Medical Electronics Co., Ltd.) includes an image optimization and speed of ultrasound-related feature, Sound Speed Index (SSI). SSI is applied in a region of interest (ROI) that could potentially aid in tissue characterization. The purpose of this study is to evaluate the reliability of SSI on various examination parameters on normal subjects.METHODSTwenty normal subjects were examined by two radiologists performing SSI measurements in the liver in different ROI depths and sizes. Intraclass correlation coefficient (ICC) was calculated to measure intra- and inter-observer variability and inter-ROI variability.RESULTSFor all ROIs and both radiologists, the mean inter-observer ICC was 0.62 and the mean intraobserver ICC was 0.52 and 0.79. The mean SSI values for all ROIs and examiners were in the range 1528.79-1540.16 m/s.CONCLUSIONThe results indicate that SSI can lead to reliable measurements on normal subjects, independent of ROI size but dependent on ROI placement. More studies processing NAFLD patients, utilizing reference methods of liver fat quantification either for reliability or correlation with SSI, should be performed to further investigate the relevance of the SSI as a potential biomarker in clinical practice for liver steatosis grading

    Muscle thickness changes during abdominal hollowing: an assessment of between-day measurement error in controls and patients with chronic low back pain

    No full text
    Spine stabilization exercises, in which patients are taught to perform isolated contractions of the transverses abdominus (TrA) during “abdominal hollowing”, are a popular physiotherapeutic treatment for low back pain (LBP). Successful performance is typically judged by the relative increase in TrA thickness compared with that of the internal (OI) and external (OE) oblique muscles, measured using ultrasound. The day-to-day measurement error (imprecision) associated with these indices of preferential activation has not been assessed but is important to know since it influences the interpretation of changes after treatment. On 2 separate days, 14 controls and 14 patients with chronic LBP (cLBP) performed abdominal hollowing exercises in hook-lying, while M-mode ultrasound images superimposed with tissue Doppler imaging (TDI) data were recorded from the abdominal muscles (N = 5 on each side). The fascial lines bordering the TrA, OI and OE were digitized, and muscle thicknesses were calculated. The between-day error (intra-observer) was expressed as the standard error of measurement, SEM; SEM as a percentage of the mean gave the coefficient of variation (CV). There were no significant between-day differences for the mean values of resting or maximal thickness for any muscle, in either group (P > 0.05). The median SEM and CV of all thickness variables was 0.71 mm and 10.9%, respectively for the controls and 0.80 mm or 11.3%, respectively for the cLBP patients. For the contraction ratios (muscle thickness contracted/thickness at rest), the CVs were 3–11% (controls) and 5–12% (patients). The CVs were unacceptably high (30–50%, both groups) for the TrA preferential activation ratio (TrA proportion of the total lateral abdominal muscle thickness when contracted minus at rest). In both the controls and patients, the precision of measurement of absolute muscle thickness and relative change in thickness during abdominal hollowing was acceptable, and commensurate with that typical of biological measurements. The TrA preferential activation ratio is too imprecise to be of clinical use. Knowledge of the SEM for these indices is essential for interpreting the clinical relevance of any changes observed following physiotherapy
    corecore